Magnesium
MAG, Mg2+
Serum (brown), Plasma (orange)
8hrs
This assay is used for diagnosing and monitoring hypomagnesaemia (magnesium deficiency) and hypermagnesaemia (magnesium excess). Hypomagnesaemia may be a cause of inappropriately low PTH levels to its role as a co-factor in the hormones synthesis.
The magnesium assay is not available on haemolysed samples. Samples contaminated with EDTA (from FBC bottles) will show falsely low levels. 
In plasma about 70 % of magnesium present in free form while the other 30 % is bound to proteins (especially albumin), citrates, phosphate, and other complex formers. Hence low levels can be seen in hypoalbuminaemia.

•       <28 days: 0.60-1.00 mmol/L

•       ≥28 days: 0.70-1.00 mmol/L

Analytical error [1] 2.0%
Reference change value [1] 11.4%